Sampling foam  compound:

 

 

The  sampling device and bottle must be clean and dry. Only new bottles should be used for despatching the sample. If previously used bottles are used, then they must be rinsed using plenty of water and dried properly. Bottles, which have  been used to store washing or cleaning agents, mineral oil products, etc. must not be used as even small amounts of residue will contaminate the foam compound sample. Drink bottles, etc. must not be used for safety reasons (risk of mistaking the contents). Tin containers must not be used for synthetic  foam compounds.
 

 

 

In the case of protein foam compound, make sure the sample bottle is completely full. Foam which is produced during transportation can increase the formation of sediment. This could result in the values of the foam compound sample changing.
 

 

At least 2 litres of concentrate are required for a comprehensive foam compound  analysis. Samples of less than 1 litre cannot be fully analysed. A minimum amount of 10 litres is required for pre-mixed solutions.
 

 

Please mark the sample clearly and specify the foam compound type, the admix ratio and the recipient of the  analysis report.
 

 

The  analysis result of the foam compound sample is based exclusively on the sample  given to us.
 

 

If you want  further information to the sampling method, request our technical instruction  sheet "sampling  foam compound.